Features ECU function
Automatic regulation
The ECU (Efficiency Control Unit) automatically adjusts the oven temperature to an efficient holding temperature after a specified time of inactivity.
Time Customisation
Users can regulate the time that must elapse without action to activate the efficient holding temperature.
Panel compatibility
Available on STC and Standard control panels, providing flexibility in implementation.
Factory preset
Comes pre-configured with a 30-minute idle time and an efficient temperature of 120°C, facilitating immediate use without the need for initial adjustments.
Reduction of energy costs. Keeping the oven at 120ºC instead of 200ºC reduces the cost/hour by 75%, reducing consumption from 1.01 kWh to 0.246 kWh.
Energy savings. The oven does not consume energy during the time it takes to cool down from 200ºC to 120ºC, approximately 1 hour and 1 minute.
Thermal efficiency. The efficient holding temperature ensures that heat losses are substantially reduced, optimising energy use.
Rapid temperature recovery. The transition from 120ºC to 200ºC takes 4 minutes and 12 seconds, allowing for a fast and efficient temperature rise.
Ease of use. Automatic activation and the possibility to customise the ECU parameters make it very easy to use and adapt to the user's specific needs
Versatility of setting time and oven control panel.
Energy consumption optimisation. Significantly reduces energy consumption by maintaining a lower temperature when the oven is not in active use.
Efficient temperature maintenance. Manages the temperature change of the oven to an efficient level (120ºC) when no action is detected on the panel or door during the set time.
Rapid temperature recovery. Allows a rapid temperature rise from 120ºC to 200ºC in approximately 4 minutes, ensuring that the oven is ready for use when required.
More information
The efficient temperature of 120°C is the result of a compromise between energy consumption, recovery time and thermal efficiency. This temperature allows economical operation without sacrificing furnace responsiveness.
The ECU is pre-set to activate the efficient holding temperature after 30 minutes of inactivity. This setting can be modified by the user to suit specific needs.
By reducing energy consumption and optimising temperature maintenance, the ECU contributes to a more sustainable and economical operation of the furnace, benefiting both the user and the environment
The ECU not only reduces costs and energy consumption, but also simplifies furnace management, allowing users to focus on other tasks while the ECU automatically manages thermal efficiency.
The flexibility and efficiency of the ECU make it ideal for use in a variety of industrial and commercial applications where cost control and operational efficiency are critical.